先安装smartmontools
apt install smartmontools
然后用命令查看
smartctl -a /dev/sda
在硬盘没有组raid0 的情况下,用这个命令就可以查看,如果组了raid0,就无法用这个命令查看了
那还另外一个命令:
smartctl -A /dev/sg0
这样就能检测到第一块硬盘的信息了
如果要看第二块第三块硬盘,就用
smartctl -A /dev/sg1
smartctl -A /dev/sg2
以此类推
20240321
smartctl -A /dev/sg0 57123
smartctl -A /dev/sg1 46732
smartctl -A /dev/sg2 30696
smartctl -A /dev/sg3 17690
20250721
smartctl -A /dev/sg0 68829
smartctl -A /dev/sg1 58440
smartctl -A /dev/sg2 37579
smartctl -A /dev/sg3 41758
20241115
查看nvme硬盘的通电时间
先用fdisk -l或者lsblk查看nvme固态的盘符
这里看到nvme硬盘的盘符是nvme0n1
用命令:
smartctl -a /dev/nvme0n1
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 33 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 21%
Data Units Read: 57,532,284 [29.4 TB]
Data Units Written: 129,316,523 [66.2 TB]
Host Read Commands: 1,330,989,637
Host Write Commands: 1,528,738,224
Controller Busy Time: 8,684
Power Cycles: 138
Power On Hours: 31,507
Unsafe Shutdowns: 119
Media and Data Integrity Errors: 0
Error Information Log Entries: 110
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 33 Celsius
Temperature Sensor 2: 36 Celsius